EPSG:5321 NAD83(CSRS) / Teranet Ontario Lambert
Projected system (Lambert Conic Conformal (2SP)) in use: Canada - Ontario. The full definition below, and conversion in one click.
| Code | EPSG:5321 |
|---|---|
| Name | NAD83(CSRS) / Teranet Ontario Lambert |
| Type | Projected system — Lambert Conic Conformal (2SP) |
| Area of use | Canada - Ontario |
| Bounds | W -95,16° · S 41,67° · E -74,35° · N 56,90° |
| Countries | Canada |
| Datum | NAD83 Canadian Spatial Reference System |
| Ellipsoid | GRS 1980 a = 6378137 m · 1/f = 298.257222101 |
| Base geographic system | EPSG:4617 — NAD83(CSRS) |
| Unit | metre (X east, Y north) |
| Transformation to WGS 84 | NAD83(CSRS) to WGS 84 (2) (EPSG:1946) — accuracy 1 m |
| Scope | Province-wide spatial data management. |
Projection parameters
| Parameter | Value | Unit |
|---|---|---|
| Latitude of false origin | 0 | degree |
| Longitude of false origin | -84 | degree |
| Latitude of 1st standard parallel | 44.5 | degree |
| Latitude of 2nd standard parallel | 54.5 | degree |
| Easting at false origin | 1000000 | metre |
| Northing at false origin | 0 | metre |
proj4 definition
+proj=lcc +lat_0=0 +lon_0=-84 +lat_1=44.5 +lat_2=54.5 +x_0=1000000 +y_0=0 +ellps=GRS80 +units=m +towgs84=-0.991,1.9072,0.5129,0.02579,0.00965,0.01166,0 +no_defs
Paste it into QGIS, proj4js, PostGIS (spatial_ref_sys) or GDAL. +towgs84 carries the EPSG transformation to WGS 84; the official code stays EPSG:5321.
WKT (ESRI format, the .prj content)
PROJCS["NAD_1983_CSRS_Teranet_Ontario_Lambert",GEOGCS["GCS_North_American_1983_CSRS",DATUM["D_North_American_1983_CSRS",SPHEROID["GRS_1980",6378137.0,298.257222101]],PRIMEM["Greenwich",0.0],UNIT["Degree",0.0174532925199433]],PROJECTION["Lambert_Conformal_Conic"],PARAMETER["False_Easting",1000000.0],PARAMETER["False_Northing",0.0],PARAMETER["Central_Meridian",-84.0],PARAMETER["Standard_Parallel_1",44.5],PARAMETER["Standard_Parallel_2",54.5],PARAMETER["Latitude_Of_Origin",0.0],UNIT["Meter",1.0]]
Other systems — Canada
- EPSG:3797NAD27 / MTQ Lambert
- EPSG:3798NAD83 / MTQ Lambert
- EPSG:3799NAD83(CSRS) / MTQ Lambert
- EPSG:3800NAD27 / Alberta 3TM ref merid 120 W
- EPSG:3801NAD83 / Alberta 3TM ref merid 120 W
- EPSG:3802NAD83(CSRS) / Alberta 3TM ref merid 120 W
- EPSG:3978NAD83 / Canada Atlas Lambert
- EPSG:3979NAD83(CSRS) / Canada Atlas Lambert
- EPSG:4122ATS77
- EPSG:4608NAD27(76)
- EPSG:4609NAD27(CGQ77)
- EPSG:4617NAD83(CSRS)
- EPSG:5320NAD83 / Teranet Ontario Lambert
- EPSG:5588NAD27 / New Brunswick Stereographic (NAD27)
- EPSG:6103NAD83(CSRS) / EPSG Arctic zone 3-29
- EPSG:6622NAD83(CSRS)v2 / Quebec Lambert
- EPSG:6623NAD83 / Quebec Albers
- EPSG:6624NAD83(CSRS)v2 / Quebec Albers
Source: EPSG registry v11.022 (IOGP), through the PROJ database. Always check a code on epsg.org before contractual work.